Reclamation of FRF

Image
  A 1200 MW coal-fired thermal power plant using Indo-Chinese Turbine EHC System in Southern India Synopsis The Power plant was suffering from loss in electricity generation for a few days as per the desired target. The O&M team has identified that the turbine command is not functioning properly and was tripping frequently. On further investigation, it was found that the Servo Valve (Moog valve) has failed and showing hunting or sluggish behavior. Minimac’s EH oil reconditioning system “MLC LVDH TRIX 20” acted as a rescuer for the plant and saved the plant from an unexpected shutdown. If this system would have implemented earlier, a loss of more than 5 Cr could be saved. Problems Failure of Moog valve:  This was the main reason for the trip of the turbine and breakdown in the power plant. Poor Oil Analysis Program:  An oil analysis is supposed to be done monthly for Particle count & TAN (weekly if the trend is negative) and weekly test for water content but the cu...

Reconditioning of EH oil

Image
  A 1200 MW coal-fired thermal power plant using Indo-Chinese turbine EHC system in southern India. Synopsis The plant was struggling with the rapid increase in TAN values in the EH oil of the governing system of the turbine. Also, the moisture content was more than permissible limits. Degradation of the oil was due to contamination ingression into the system resulting in by-product formation. Minimac’s EH oil reconditioning system  “MLC LVDH TRIX 20”  proved to be the savior and an unexpected shutdown of the turbine  worth ₹1.05 Cr per day was saved. Problems A rapid increase in the Total Acid Number (TAN) could degrade the EH oil and lead to the possibilities of failure of servo valve, hunting, power generation loss, unplanned shutdown, etc Oil analysis was done to check the properties of EH oil like moisture, NAS value, total acid number. Solutions Installation of Minimac’s EH oil reconditioning system  “ MLC LVDH TRIX 20 ”  comprehensively designed with...

PE fluid reconditioning in turbine EHC system

Image
  A 1,320 MW (2 x 660 MW), one of the first and largest supercritical coal-fired power plants using Indo-Chinese turbine EHC system in northern India Synopsis The plant was struggling with the rapid increase in TAN values in the EH oil of the governing system of the turbine. Moisture content was also more than permissible limits. Degradation of the oil was due to contamination ingression into the system resulting in by-product formation. Minimac’s EH oil reconditioning system  “MLC LVDH TRIX 20”  acted as a savior for the plant and as a result the unexpected shutdown of the turbine worth ₹1.4 Cr per day was saved. Problems Degradation of EH oil properties at both the units of the plant. The installed regeneration system for each EHGC tank of unit #1 and #2 was failing to control neutralization number (TAN value) and showing a rapid increase in the same The company was unaware of the consequences of increased TAN values like possibilities of failure of servo valve, hunting...

Reconditioning of EH oil

Image
  A power plant in Northern India using Indo- Japanese technology turbine EHC system saved 1.5 Cr approx. with MLC LVDH TRIX-20 EH Oil Filtration Synopsis A Power plant (2 x 600 MW) in the Northern region of India was struggling with the rapid increase in TAN values in the EH oil of the governing system of the turbine and moisture content was also more than permissible limits. Degradation of the oil was due to contamination ingression into the system and resulting in the formation of by-products. Minimac’s EH oil Reconditioning system “MLC LVDH TRIX 20 “acted as a savior for the plant which has escaped the unexpected shutdown of the turbine worth 1.05 Cr per day (approx. 15 hours downtime) and cost & effort for Replacement of oil worth 44 lakhs. In total, the company has saved around 1.5 Crore by installing external Reconditioning system at their site The above graph shows the trend analysis of NAS 1638, Moisture and TAN value during one-month installation of the reconditioning...